PT-500 Pressure Sensor

$699.95

Monitor liquid levels with a Pressure Transducer and a ControlByWeb® module Receive text messages or email alerts when a user-specified level is reached. Log and plot the level history, and more.

Call to Order

Max Water Depth: Up to 575 ft.

Modbus RS-485 | 4-20mA

Frequently Bought Together

Call to Order

Pressure Transducer & Level Monitoring

Monitor liquid levels with a Pressure Transducer and a ControlByWeb® module (See recommended products below) Receive text messages or email alerts when a user-specified level is reached. Log and plot the level history, and more.

How do Pressure Transducers Work

Submersible pressure transducers work just like other pressure transducers, except they’re inside a water-tight housing, and they read in feet or inches of liquid (adjusted to specific gravity) rather than PSI.

When a pressure sensor is installed near the bottom of a tank. It uses an internal diaphragm which flexes with changes in pressure. This flexing sends an electrical signal to the attached ControlByWeb module which automatically calculates the depth. This data can then be viewed using a standard web browser over an IP network.

Pressure Tank Mounting  Dirty Water Diagram

Liquid Types

The PT-500 is ideal for clean liquids and can be fitted with a protective cage, making it well suited to handle dirty liquids.

Stainless Steel Enclosure

The PT-500 Series are enclosed in stainless steel, making them compatible with most chemicals.

Clean Liquid Icon
Dirty Liquid Icon
Corrosive Liquid Icon

Sensor Output

Modbus RS-485

Easily configure sensor data using the X-404 Modbus Master Controller. No voltage scaling required!

4-20mA

For exisiting systems that require 4-20mA, connect the sensor to one of our compatible devices (X-418, X-420, X-22s).

Tank Vents – Submersible Sensor

Thread the PT-500 Pressure Transducer through vents in a tank.
Tank must be vented to atmosphere.

Pressure Tank Mounting Diagram

Head Pressure

Connect the pressure transducer to the head pressure to monitor tank levels.
Tank must be vented to atmosphere.

PT-500 Head Pressure Example Diagram

Sensor Specifications

 PERFORMANCE
  • Max Water Depth: Up to 575 ft. (175.25m)
  • Pressure Range: Up to 250 psig
  • Accuracy: B.F.S.L. ≤ 0.25% of span
    1 year stability ≤ 0.25% of span
  • Temp. Compensation Range: 32 to 122°F (o to 50°C)
  • Temp. Error (reference temp 70°F):
    Zero: ≤ 0.025% F.S./°F | Span: ≤ 0.025% F.S./°F
OUTPUTS
  • RS-485 Modbus | 4-20mA
  • Call to configure
ELECTRICAL
  • Lightning Protection: Built In, Protected against reverse polarity, surge per IEC 61000-4-5
  • External Power: 10-28 VDC
  • Vented Urethane Cable: Tensile Strength up to 200 lbs
APPROVALS
  • Lightning Protection: Compliant with IEC 61000-4-5 Standards for electrical surges
  • Intrinsically Safe: 4-20mA, Class 1, Div. 1 Groups C & D
  • Single Seal
INTERNET CONNECTIVITY
  • NO CLOUD NEEDED! Remote connection available with ControlByWeb devices (see below)
PROGRAMMING
  • Automatic programming via ControlByWeb device
SENSOR MATERIAL OPTIONS
  • 316L SS Sensor | Urethane Cable | Hytrel® Cable | PVC Cable | Delrin™ Nose Cone
ENVIRONMENTAL
  • Operating Temp: -40°C to 85°C
  • Enclosure Protecton: Submersible to 575 ft.
INSTALLATION
  • Top of tank | Head pressure | Simple to install and program

Control Pumps Using Submersible Pressure Transducer Data

PT-500 Pump Control Example Diagram

Control Options

In addition to simple remote monitoring, ControlByWeb modules are fully programmable and provide custom control capabilities as well. For example, you can connect a pump to a relay on a ControlByWeb module and remotely run the pump manually, or configure the pump to automatically run if the level gets too low.

Level Monitoring in Hazardous Environments

Warning: Use of these products to monitor tank levels of potentially explosive liquids or substances (such as gasoline), requires strict adherence to local safety laws and regulations. ControlByWeb modules (such as the X-404, X-420, etc) are NOT designed to be intrinsically safe and must be installed with both physical and electrical safety barriers. Installation should only be performed by qualified individuals and companies who understand the safety requirements. Please refer to sensor installation manuals and consult local safety regulations for more information.

Intrinsically Safe Modbus Monitoring Example Diagram
Intrinsically Safe 4-20mA Monitoring Example Diagram

Common Industries

Wastewater Lift Station Image

Wastewater Lift Station

Ideal for a variety of chemicals, the PT-500 can monitor liquid levels in wastewater lift stations.

Low Cost Tank Monitoring Image

Tank level monitoring

Monitor tank levels for tanks with limited access points (i.e., Vents, Head Pressure).

Wastewater Leachate Tank Image

Wastewater Leachate Tanks

Prevent Sanitary Sewer Overflows (SSOs) with the PT-500 and ControlByWeb controllers.

Shopping Cart